• Goniometer
    »ó¼¼ ±Ô°Ý Ç¥
    Cat. No. Model Description
    M01-680-910 X-GSM40-KX13A Motorized goniometer stage, 40 mm centre of rotation, integrated controller, North America, 48 V. Powers one axis
    M01-680-913 X-GSM40-KX14A Motorized goniometer stage, 40 mm centre of rotation, integrated controller, North America, 48 V. Powers multiple axes
    M01-680-916 X-GSM60-KX13A Motorized goniometer stage, 60 mm centre of rotation, integrated controller, North America, 48 V. Powers one axis
    M01-680-919 X-GSM60-KX14A Motorized goniometer stage, 60 mm centre of rotation, integrated controller, North America, 48 V. Powers multiple axes
    • Goniometer Specification
    »ó¼¼ ±Ô°Ý Ç¥
    Specification
    Value
    Model X-GSM Series
    Built-in Controller Yes
    Accuracy (unidirectional) 0.06 degrees
    Repeatability < 0.005 degrees
    Backlash < 0.01 degrees
    Maximum Speed 30 deg/s
    Encoder Type None
    Communication Interface RS-232
    Communication Protocol Zaber ASCII (Default), Zaber Binary
    Maximum Centered Load 30 N
    Guide Type Crossed roller bearing
    Rotation Centre Accuracy < 0.1 mm
    Maximum Current Draw 350 mA
    Power Supply 24-48 VDC
    Power Plug 2-pin Screw Terminal
    Motor Steps Per Rev 200
    Motor Type Stepper (2 phase)
    Inductance 3.5 mH/phase
    Default Resolution 1/64 of a step
    Data Cable Connection Locking 4-pin M8
    Motor Frame Size NEMA 08
    Mechanical Drive System Precision Worm Gear
    Limit or Home Sensing Magnetic home and away sensors
    Manual Control Yes
    Axes of Motion 1
    Mounting Interface M2 and M3 mounting holes
    Vacuum Compatible No
    Operating Temperature Range 0-50 degrees C
    RoHS Compliant Yes
    CE Compliant Yes
    Weight 0.271 kg